Amann Girrbach clinometer Instrucciones De Uso página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

A P P L I C A T I O N
Laboratory clinometer
Model transfer in the Artex articulator
E N
Articulate the maxillary model using facebow
registration. The cranium-axis-oriented model
articulation is mandatory. This can be done by
direct adaptation of the facebow on the articula-
tor or by indirect transfer via transfer stand or
transfer table.
Mounting the laboratory clinometer on the
Artex articulator
▷ Set the angle value indicated by the dentist on
the laboratory clinometer, e.g. 1° A:
▪ Turn the large rotation knob in the desired
direction (here in direction A) and align the
zero line with the first line.
▪ Secure the adjustment with the small counter
screw against unintentional twisting.
▷ On the Artex articulator, replace the standard
anterior incisal pin against the cranked pin.
The cranked pin later allows a clear view of the
front section of the model.
Fig. 8
Cranked pin in articulator
18
▷ Loosen the support pin of the upper articula-
tor part.
▷ At the rear slot, slide the laboratory clinometer
in to the stop against the support-pin thread.
The support pin serves as hinge for the labora-
tory clinometer.
▷ Unscrew the fixing screw of the anterior
incisal pin holder so far that the clinometer
can be pivoted to the stop at the thread under
the fixing screw.
▷ Pivot the clinometer in to the stop.
Fig. 9
▷ Tighten the support-pin and fixing screw in
order to secure the clinometer.
Fig. 10
To pivot out (swivel out sidewards) the
clinometer, loosen the support-pin and
fixing screw minimally.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

219950219950c

Tabla de contenido