SICK CMB Serie Instrucciones De Uso página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
OPERATING INSTRUCTIONS
10.3
Reduction factors
en
10.4
Process data structure
26
O P E R A T I N G I N S T R U C T I O N S | CMB
Table 9: Non-flush installation, M12 male connector
CMB18-12NPPEW2SA00
85
(3.35)
70
(2.76)
15
8
(0.31)
(0.59)
Table 10: Reduction factors
Metal
Water
PVC
Oil
Glass
Ceramics
Alcohol
Wood
NOTE
The values are reference values which can vary.
Table 11: Process data structure
IO-Link
Process data
Bit 0 + 1 / data type
Bit 2 + 3 / data type
Bit 4 + 5 / data type
Bit 6 / data type
Bit 7 / data type
Byte 2 / data type
Byte 0 + 1 / data type
Analog value (Analogue value): The value is between 0 and 10,000 digits. It increases the
closer the measuring object is to the sensor surface. An object with higher permittivity
also increases the value.
Switching signal QL1 and Switching signal QL2 (output signals): Switching signal generated
from smart task
Detection output Qint.1 and Detection output Qint.2 (output signals): Detection output before
smart task
CMB30-25NPPEW2SA00
74
61
(2.4)
LED
14.5
(0.57)
1
1
Approx. 0.4
Approx. 0.25
0.6
0.5
0.7
0.2...0.7
Byte 0: Bits 31...24
Byte 1: Bits 23...16
Byte 2: Bits 15...8
Byte 3: Bits 0...7
Q
Qint. detection output 1+2 / Boolean
Dust alarm 1+2 / Boolean
Temperature alarm / Boolean
Short-circuit / Boolean
Analog values / UInt16
(2.91)
LED
CMB...A00
V1.1
4 bytes
/ Boolean
L1+L2
8027571/2022-03-07 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cmb18Cmb30

Tabla de contenido