Operation
LuminIce® II Reminder
The LuminIce® growth inhibitor recirculates the air in the ice
machine foodzone over a UV bulb. This process will inhibit
the growth of common micro-organisms on all exposed
foodzone surfaces.
The LuminIce® II has a feature that displays a reminder to
change its bulb every 12 months.
1. From the Set-Up menu, use the Down arrow to highlight
LUMINICE.
2. Press the Checkmark. On this screen, you can choose to
turn the reminder to AUTO or OFF by highlighting your
choice and pressing the Checkmark. Selecting one will
deselect the other.
3. When the check reflects your preference, use the Down
arrow to navigate to Exit and press the Checkmark. The
display will return to the Set-Up menu.
USB Setup
Refer to "Upgrading Firmware with a Flash Drive" and
"Exporting Data to a Flash Drive" for more information on
this setting.
34
ENERGY SAVER MENU
From the Main menu, use the Down arrow to navigate to
Energy Saver and press the Checkmark. Set up an energy
saving ice program, enable the Water Miser and view usage
statistics from this menu. Press the Left arrow to return to
previous screens.
Energy Saver
Energy Saver Menu
Ice Program
To save energy and water, the ice machine can be
programmed to only power up during time periods that the
ice will be used or when the bin level is being depleted by
heavy use.
Important
Setting an ice program will take the ice machine out of
the On/Off Mode and the Power button will be disabled.
1. In the Energy Saver menu, ensure that Ice Program is
highlighted.
2. Press the Checkmark. On this screen, you can choose to
turn on the time program or the bin level program by
highlighting your choice and pressing the Checkmark.
Selecting one will deselect the other. If one of them is
selected and you wish to turn both off, highlight the
choice and press Checkmark again.
3. If neither of the programs is selected, highlighting Next
and pressing the Checkmark will simply return to the
top of this screen. If one of the programs is selected,
highlight Next and press the Checkmark to choose the
times or bin levels. NOTE: For details on how to use
the cursor for the time program, refer to "Display Panel
Navigation" in this section.
4. Select Exit to return to previous screens and again to the
Energy Saver menu.
Part Number: 000013325 Rev 02 6/17
Section 3
Ice Program
Water Miser
Statistics
Exit