Maximum Breaker Size & Minimum Circuit Amperage Chart - Manitowoc 820C Serie Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 2
Maximum Breaker Size & Minimum Circuit Amperage Chart
NOTE: Due to continuous product improvements, this information is for reference only. Please refer to the ice machine data
plate to verify electrical data. Data plate information overrides information listed on this page.
Voltage/Phase/
Ice Machine
Cycle
115/1/60
I0300
230/1/50
230/1/60
115/1/60
I0320
208-230/1/60
230/1/50
115/1/60
I0450
208-230/1/60
230/1/50
115/1/60
I0500
208-230/1/60
230/1/50
115/1/60
I0520
208-230/1/60
230/1/50
208-230/1/60
I0600
230/1/50
208-230/1/60
I0606
230/1/50
208-230/1/60
I0850
208-230/3/60
230/1/50
208-230/1/60
I0906
208-230/3/60
230/1/50
208-230/1/60
208-230/3/60
I1000
230/1/50
380-460/3/50-60
208-230/1/60
208-230/3/60
I1100
230/1/50
380-460/3/50-60
208-230/1/60
I1106
208-230/3/60
230/1/50
208-230/1/60
I1200
208-230/3/60
230/1/50
208-230/1/60
208-230/3/60
I1400
230/1/50
380-460/3/50-60
208-230/1/60
208-230/3/60
I1406
230/1/50
380-460/3/50-60
208-230/1/60
208-230/3/60
I1800
230/1/50
380-460/3/50-60
208-230/1/60
208-230/3/60
I1806
230/1/50
380-460/3/50-60
Part Number: 000013325 Rev 02 6/17
Air-Cooled
Maximum
Minimum
Fuse/Circuit
Circuit Amps
Breaker
15
10.8
15
6.1
15
6.1
15
11.5
15
6.0
15
6.0
20
13.2
15
6.6
15
7.1
20
14.2
15
6.1
15
7.1
20
14.4
15
6.1
15
7.1
15
10.2
15
6.7
15
11.1
15
6.7
20
11.9
15
9.2
20
10.8
20
12.2
15
9.7
20
12.2
20
13.5
15
9.5
20
13.7
N/A
N/A
20
13.5
15
9.5
20
13.7
N/A
N/A
20
13.0
15
9.8
15
9.0
25
25.0
20
16.0
20
13.7
30
18.3
20
13.2
30
15.9
N/A
N/A
30
15.9
20
12.3
30
15.8
N/A
N/A
40
23.8
25
15.4
30
18.3
N/A
N/A
40
23.8
25
15.4
30
18.3
N/A
N/A
Water-Cooled
Maximum
Minimum
Fuse/Circuit
Circuit Amps
Breaker
15
10.0
15
5.6
15
5.7
15
10.7
15
5.6
15
5.6
20
12.5
15
6.2
15
6.8
20
13.5
15
5.7
15
6.8
20
13.5
15
5.7
15
6.8
15
9.7
15
6.1
15
10.7
15
6.1
20
10.9
15
8.2
20
9.4
20
11.2
15
8.7
20
11.2
15
9.7
15
8.5
20
12.3
15
4.5
15
9.7
15
8.5
20
12.3
15
4.5
15
11.9
15
8.7
15
8.7
25
25.0
20
16.0
20
12.3
30
16.9
20
11.8
30
15.9
15
6.4
30
14.3
20
11.3
30
14.2
15
6.4
40
22.4
25
14.0
30
16.9
15
6.5
40
22.4
25
14.0
30
16.9
15
6.5
Installation
Remote
Maximum
Minimum
Fuse/Circuit
Circuit Amps
Breaker
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25
20.0
N/A
N/A
15
6.7
N/A
N/A
N/A
N/A
N/A
N/A
15
10.7
15
7.1
15
11.7
15
7.1
20
11.9
15
9.2
15
10.4
20
12.2
15
9.7
15
12.2
15
10.7
15
9.5
20
12.3
N/A
N/A
15
10.7
15
9.5
20
12.3
N/A
N/A
15
12.9
15
9.7
15
9.7
N/A
N/A
N/A
N/A
N/A
N/A
30
17.9
20
12.8
30
16.9
N/A
N/A
30
14.9
20
12.3
30
16.9
N/A
N/A
40
23.4
25
15.0
40
17.9
N/A
N/A
40
23.4
25
15.0
30
17.9
N/A
N/A