Maintenance

Parts Removal for Cleaning/Sanitizing

SINGLE EVAPORATOR ICE MACHINES

A. Remove the water curtain
• Gently flex the curtain in the center and remove it from
the right side.
• Slide the left pin out.
B. Remove the ice thickness probe
• Compress the hinge pin on the top of the ice thickness
probe.
• Pivot the ice thickness probe to disengage one pin then
the other. The ice thickness probe can be cleaned at this
point without complete removal. If complete removal is
desired, disconnect the ice thickness control wiring from
the control board.
C. Remove the water trough
• Depress tabs on right and left side of the water trough.
• Allow front of water trough to drop as you pull forward to
disengage the rear pins.
A
42
D. Remove the water level probe
• Pull the water level probe straight down to disengage.
• Lower the water level probe until the wiring connector is
visible.
• Disconnect the wire lead from the water level probe.
• Remove the water level probe from the ice machine.
E. Remove the water distribution tube
NOTE: Thumbscrews for the distribution tube are retained
to prevent loss. Loosen thumbscrews, but do not pull
thumbscrews out of distribution tube.
• Loosen the two outer screws (do not remove screws
completely because they are retained to prevent loss)
and pull forward on the distribution tube to release from
slip joint.
• Disassemble distribution tube by loosening the two (2)
middle thumbscrews and dividing the distribution tube
into two pieces.
E
O f f
O n / O f f M o d e
[
!
]