Televes MTS 100 Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Field meter
MTS 100
MONITOR
TV mode
Type
Sensitivity
Synchronism mode
Spectrum function
Full Span mode
Variable Span mode
Video input / output
Connector
Impedance
Input
Sensitivity
Max. level
Output
Output level
Switching control
Monitor controls
SOUND
Demodulation
Output power
Volume control
Output
POWER TO THE EXTERNAL UNITS
Voltage
22 KHz tone
Maximum intensity
5.2" screen
B/W. Multistandard B, G, H, D, K, I/L, CCIR standard
40 dBµV for the correct synchronism
Operating mode with lateral displacement of the picture to
show the synchronism pulse and the burst if the signal is
coded in colour.
Spectrum of the entire band selected with marker on the fre-
quency tuned.
Panoramic display of the frequency spectrum around the fre-
quency tuned.
6 pins
75 Ω
Pins 1 - 2 (1 GND)
1 Vpp, positive video
3 Vpp
Pins 3 - 4 (3 GND)
1 Vpp, positive video.
Pin 5 (+ 12V / 1K).
Brightness, contrast and horizontal zoom
FM and TV, monaural selectable
1 W, built-in speaker
Yes
For external headphone. 3.5 mm stereo jack socket.
Monaural sound.
0/13/18 V
ON/OFF
400 mA
User
manual
20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

4210

Tabla de contenido