for how you will use it, temperature and water units, etc.
Type
—Select the type of machine shown on the machine name plate. The name plate is on the
1.1.1.2.
1.1.
back side of the machine.
Name
—Set a machine name to describe the machine on printed reports.
1.1.1.2.
1.2.
Laundry Type
1.1.1.2.
1.3.
the 10 default formulas available without programming. This version of the machine software
provides default formulas for the commercial configuration.
Language
—Set a language for the machine prompts. The only current choice is English.
1.1.1.2.
1.4.
Water Unit
—Set whether bath height will be displayed and programmed in inches or
1.1.1.2.
1.5.
centimeters.
Water Offset
1.1.1.2.
1.6.
the same as the actual bath level in the machine.
Water Levels
1.1.1.2.
1.7.
Water Level 6 must be the highest.
Temperature Probe
1.1.1.2.
1.8.
sensor allows programming a specific temperature for each bath step.
Temperature Unit
1.1.1.2.
1.9.
degrees Fahrenheit or degrees Celsius.
Steam Error
1.1.1.2.
1.10.
bath temperature.
Cooldown Error
1.1.1.2.
1.11.
programmed bath temperature.
Extra Water
—Set whether this machine is attached to a third water source.
1.1.1.2.
1.12.
Reuse Drain
1.1.1.2.
1.13.
RinSave
—Set whether to allow RinSave steps in wash formulas.
1.1.1.2.
1.14.
Fill Error
—Set the maximum time allowed for the machine to fill to the desired level.
1.1.1.2.
1.15.
Counts per 10 RPMs
1.1.1.2.
1.16.
change the basket speed by 10 RPMs. Do not make a change to this value before you consult with
the Milnor factory.
Password Menu button
1.1.1.2.
1.17.
and manual functions. Also, set the date and time for the machine.
—Set the type of goods this machine will process most often. This selection sets
—Set a digital counts value here so the displayed bath level on the Run screen is
—Set a value for each water level. Water Level 1 must be the lowest level, and
—Set whether this machine has a temperature sensor. A temperature
—Set whether bath temperature will be displayed and programmed in
—Set the time allowed for the machine to use steam to achieve the programmed
—Set the time allowed for the machine to complete a cooldown to a
—Set whether this machine has a reuse tank and a second drain valve.
—Set the number of counts from the digital-to-analog board required to
—Set a password to restrict access to programming, configuration,