Table electronic control panel alarm: EO and E1 flashing.
Corrective Action.
If the display shows one or more of the alarm code(s) listed above, take note of it, turn off the electronic control panel
and turn it on again after a few seconds.
If the code(s) is/are displayed again, call technical service and report the code(s) noted.
6.2 FOOD STORAGE (fig.5)
In order to achieve optimal operation of the case, the following instructions should be observed:
- Insert goods into the appliance only after reaching the desired operating temperature indicated on the digital
display.
- Do not place uncovered hot food or liquids inside the appliance.
- If possible, pack or protect the food.
- Do not restrict air circulation inside the cell with unnecessary obstructions.
- Avoid frequent or prolonged opening of doors/drawers.
- Wait a few moments before reopening the door/drawer immediately after it is closed.
When refueling, open and fill only one drawer at a time to eliminate the risk of imbalance.
of excessive imbalance or request fixed feet from the supplier. The available space is shown in Fig. 5.
6.3 DEFROSTING (fig.6)
6.3.1 DEFROST TIMER
The electronic control panel automatically performs 4 defrosts in 24 hours.
The timer resets at the time of the first power-on. To change the start time
To change the start time of the defrost cycle to the desired time, press the appropriate key (DEF
or dripping snow) for more than 5 seconds, a defrost cycle will start immediately
defrost and the next one will start after 6 hours. During
defrosting, an LED (DEF) will light up.
6.3.2 MANUAL DEFROST
All tables defrost automatically (see § 6.3.1). To manually start the
defrost act as mentioned above to change the start time of the defrost cycle (see § 6.3.1).
For condensation water removal see §.4.4.
7. MAINTENANCE
7.1 Periodic cleaning
29