For hygienic reasons and to improve performance, clean the inner basin at least once a week.
Perform a manual defrost cycle first (par.6.3), once finished, turn off the power and clean the interior following the
instructions in par.4.2 (initial cleaning).
7.2 CLEANING THE CONDENSER (fig.7)
To improve performance, clean the condenser at least once a week.
Before starting, turn off the equipment and unplug, close and protect the equipment.
- unscrew, rotate and remove the protective grille.
- remove dust deposited on the front surface of the condenser using a
brush and a vacuum cleaner and restore the previous condition.

7.3 CABINET IDLE PERIOD

During idle periods, remove the products from the cabinet and follow the following directions:
- Remove the plug from the power outlet and clean the appliance thoroughly for the
periodic cleaning
- Cover the cabinet with a cloth to allow air circulation inside.

8. TROUBLESHOOTING AND SOLUTIONS

Often a unit malfunction is due to simple causes that can be easily
eliminated without contacting a technician. Therefore, perform the
following checks
8.1 IF THE UNIT DOES NOT WORK, CHECK THAT :
The plug has been properly inserted into the socket,
the power cord is not damaged.
8.2 IF THE DESIRED TEMPERATURE IS NOT REACHED, CHECK THAT:
- the control switch is on ;
- the electronic control panel is correctly adjusted (see § 6.1.3, 6.1.4);
- the cabinet is neither defrosting nor post-defrosting;
- the evaporator is not covered with frost (see § 6.3);
- the condenser is not obstructed by dust;
- the cabinet is not located near heat sources or its condensing unit has uninterrupted air flow;
- stained food or other objects do not inhibit the proper closing of the unit.