INSTALLATION AND CIRCUIT – Connection of options
Example 3
You want to add:
A 60W GPS,
A 60W radio,
A 120W audio warning.
A
Bilge fan
Radio
Depth sounder
GPS
Searchlight
Alarm system
Refrigerator
VHF
Σ
Some manufacturers will indicate the amperage rather than the absorbed
power. For direct current (the case here), simply multiply by 12 to obtain
NOTE:
the power and divide the power by 12 to obtain the device's current
consumption.
III-2-6-2-Wiring
1 Choose a free fuse location,
Connect the power supply of your accessory to the terminal corresponding to this slot
using a 6mm female tab type terminal lug,
If you have to add cable for the connection, use cable with a cross-section of at least
1.5mm² complying with "navy" type recommendations (UL1426 or SAE J378 or SAE J1127
or SAE J1128 or in general meeting ABYC and/or EC recommendations),
Connect the earth cable of your accessory to the ground terminal strip using a Ø5 "ring
terminal" (same remark as previously for the cable),
Insert an ATO type fuse with a max current of 15A and greater than the load current of
your device.
60W
60W
120W (< 180W)
CONCLUSION
and
B
Miscellaneous
lighting
Miscellaneous
electronic equipment
Shower pump
Max power
32
120W (> 60W)