Installation
5.
Refer to picture and install LuminIce®
hoses, wire clip and secure wires to
clip.
Install wire clip and route wires
along evaporator bulkhead
6.
Install the notched evaporator dust
cover from kit.
NOTE: Proceed to the next step for your
specific LuminIce® kit number. Installation
varies depending on whether power for the
LuminIce® is supplied by the control board
or a switching power supply needs to be
installed.
10
K00464 & K00465 INDIGO® NXT MODELS
LOW VOLTAGE WIRE INSTALLATION
Power is supplied from the control board.
1.
Route the low voltage wiring harness
from the control board to the
LuminIce®. Install wire clip and route
wires close to evaporator bulkhead
to assure harness is away from any
moving parts, then snap wire harness
connectors together.
2.
Route the low voltage wiring harness
through the control box low voltage
Heyco fitting and connect to the
control board LuminIce® connector.
3.
Test run the ice machine and
LuminIce®. A noticeable draft will be
emitted from the upper hose adapter
during operation.