Section 2
Wires Removed From Contactor
LuminIce® Power
Step 2
Route LuminIce® hoses to
evaporator and attach.
• Insert hose closest to the control box
in the bottom evaporator bulkhead
hole.
• Insert the other hose in the upper
evaporator bulkhead hole.
5.
Install the evaporator dust cover
and test run the ice machine and
LuminIce®. The LuminIce® is energized
whenever power is applied to the ice
machine.
Part Number: 000014110 Rev 01 1/19
L2
L1
Line Voltage
Power Supply
Indigo® NXT or Indigo® Two-
Evaporator Ice Machine Model
Installation K00434, K00451 Indigo®
& K00465 Indigo® NXT
Disconnect power to ice machine at the
electrical disconnect. Pressing the power
button does not disconnect line voltage.
1.
Disconnect all power to the ice
machine at the electrical disconnect.
2.
To allow access for LuminIce® tubing,
the plastic caps in the evaporator
compartment bulkhead wall must be
removed and discarded. Cap located
behind evaporator will fall into the
water trough. Remove water trough to
retrieve cap, then discard.
Remove Plastic Caps From
3.
Cut hose to length.
• Cut one hose 8" (20 cm) long.
• Cut one hose 18" (46 cm) long.
4.
Assemble LuminIce®.
• Assemble LuminIce® to bracket.
• Install tubing and secure with hose
clamps.
• Insert a tubing adapter into each
hose.
Installation
Warning
Evaporator Bulkhead
15