7. TROUBLE SHOOTING

Problem
The tool does not work
Air is coming out of the safety
valve
There is no or insuffi cient
extraction
The trigger does not work
The blind rivet cannot be
placed into the nose piece
The blind rivet is not set
correctly
The rest mandrel does not
release from the nose piece
During setting the rivet
mandrel does not break
The rest mandrel is not
extracted into the mandrel
collector
The air supply unit cannot be
turned 360°
The tool does not perform well
consistently
14
Cause
The tool has not been connected to
the air connection
The air supply closing valve is still
closed
There is insuffi cient air pressure
The air pressure is too high
The extraction has not been turned on
There is insuffi cient air pressure
The mandrel collector is full
The tool is blocked by rest mandrels
There is insuffi cient air pressure
The incorrect nose piece has been
mounted
The tool is blocked by rest mandrels
Contaminated or worn clamping jaws
There is insuffi cient air pressure
The capacity of the tool has been
exceeded
The incorrect nose piece has been
mounted
The tool is blocked by rest mandrels
There is insuffi cient air pressure
The capacity of the tool has been
exceeded
The incorrect nose piece has been
mounted
The tool is blocked by rest mandrels
The mandrel collector is full
The tool is still under air pressure
O R I G I N A L I N S T R U C T I O N

Corrective action

Connect the tool to the air connection
Open the air supply closing valve
Use the correct air pressure 5-7 bar
Use the correct air pressure 5-7 bar
Check the position of the mandrel collector
Use the correct air pressure 5-7 bar
Empty the mandrel collector
Remove the rest mandrel
Use the correct air pressure 5-7 bar
Mount the correct nose piece
Remove the rest mandrel
Clear or replace the clamping jaws
Use the correct air pressure
Use the correct tool
Mount the correct nose piece
Remove the rest mandrel
Use the correct air pressure
Use the correct tool
Mount the correct nose piece
Remove the rest mandrel
Empty the mandrel collector
Close the air supply closing valve and
depressurize the tool by turning on the
extraction or by operating the trigger
Contact a service centre