Approvals - Sagola 6110 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
34/35
Never exceed the maximum operating pressure. The equipment units are calibrated by the ma-
nufacturer in accordance with the design performance features described in their technical spe-
cifications.
As a general, preventive measure we advise you to wear goggles in accordance with
the specific environmental regulations and characteristics for the work centre.
Wear gloves when handling the product (see the manufacturer's recommendations)
and clean the gun.
If, when the gun is in use, the ambient noise level exceeds 85 dB (A) the use of appro-
ved ear protectors is required.
The unit in itself does not propitiate any mechanical risk of perforations, impact or pinching,
except those deriving from incorrect installations and handling.
USE SAGOLA ANTI-STATIC HOSES TO ELIMINATE POSSIBLE ELECTRICAL
SHOCK THAT MAY LEAD TO A RISK OF FIRE OR EXPLOSION.
Pay adequate attention when handling the unit in order to prevent any damage that might lead
to dangerous situations for the user or personnel standing near the unit, as a consequence of
leaks, breakages, etc.
The equipment has been designed for use at room temperature. The maximum operating tem-
o
perature is 50
C.
The use of solvents and/or detergents that contain halogenated hydro-
carbons (trichloroethane, methyl chloride, etc.), may cause chemical
reactions in the unit as well as in its zinc-coated components (trichloroe-
thane mixed with small amounts of water produces hydrochloric acid).
For this reason, these components may rust and in extreme cases the
chemical reaction caused may be explosive. We recommend you to use
products that do not contain the aforementioned components. Do not
use acids, soda (alkalis or pickling substances, etc.) for cleaning under
any circumstances.
In general, precautions must be taken whenever the unit is handled, in order to prevent any
damage to this.
Connectors must be securely tightened and in good condition. If pneumatic connectors are
fitted, they must comply with the standard ISO 4414:2010.
Safety standards must be understood and applied.
Any non-compliance with the indications set out in this manual may lead to incidents affecting the
physical integrity of the user or other personnel or animals.
Respect and comply with indications relating to the conservation of the environment.
Always keep the safety sheets for the products to apply and the cleaning liquids to hand in case
you need to consult them.

13. Approvals

SPAIN - Approved by the Ministry of Industry and Energy with the numbers AP 1070 FBZ 2330.
FRANCE - Constructed according to CODAP standard, and in accordance with the Ministerial Or-
ders dated 18/01/43 and 24/03/78.
GREAT BRITAIN - Constructed according to standards BRITISH STANDARD 1101-1977.
GERMANY - Constructed according to standards A.D. MERKBLÄTTER.
ENGLISH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

652653

Tabla de contenido