CALCULATING VENT SYSTEM LENGTH

To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
7" (17.8 cm) Round Vent System
Vent piece: 45° elbow
Vent piece: 90° elbow
Length: 2.5 ft (0.8m)
Length: 1.5 ft (0.8m)
Vent piece: 3¹⁄
4
" x 10" (8.3 cm x 25.4
cm), 4.5 ft to 7" (17.8 cm)
Length: 4.5 ft (1.4m)
Example Vent System
7" (17.8 cm) round
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
3
" x 10" (8.3 cm x 25.4 cm) Vent System
1
4
Vent piece: 90° elbow
Vent piece: 90° elbow
Length: 5.0 ft (1.5m)
Length: 12.0 ft (3.7m)
Example Vent System
3 " x 10"
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 3¹⁄
" x 10"
4
(8.3 cm x 25.4 cm) system
Vent piece: 7" (17.8cm)
wall cap
Length: 0.0 ft (0.0m)
Vent piece: 3¹⁄
4
" x 10" (8.3 cm x 25.4
cm), to 7" (17.8 cm) 90° elbow
Length: 5.0 ft (1.5m)
Wall cap
6 ft (1.8 m)
= 50 ft (15.2 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
Vent piece: 3¼" x 10"
wall cap
Length: 0.0 ft (0.0m)
Wall cap
= 35 ft (10.7 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)

BEFORE INSTALLING THE HOOD

Recommended mounting height is 24" from the bottom of the range hood to the top
of the cooking surface.
The hood should be mounted to the bottom of a standard wall cabinet. If the hood must
be mounted directly to a wall, secure the hood to wall studs.
All wiring must comply with local codes and the unit must be properly grounded. The
hood is connected to a 110 - 120 VAC lighting circuit (15 Amp) in the circuit breaker or
fuse box.
The model EFS130 is ducted
The models ENM230 and ENM236 are convertible (they may be installed as a ducted or
as a non-ducted unit).
If the range hood is to be non - ducted:
Purchase Accesories Recirculation (non ducted) kit
ENM230 / ENM236: ENMRCK36
If the range hood is to be ducted:
Ductwork can be installed vertically or horizontally.
Duct runs should be as short as possible.
Avoid the use of elbows.
Use duct tape at all joints.
Do not use duct smaller than the discharge on the hood.
For 7" round ductwork installation, purchase accessory transition Kit:
7" (17.8 cm) round vent mounting plate.
Accesories Part No. EXXTRK07 (purchased separately).
7" (17.8 cm) round damper Non return valve.
Accesorie Part No. EXXNRVRD (purchased separately).
For 3¼" x 10" (8.3 x 25.4 cm) rectangular ductwork installation:
3¼" x 10" (8.3 x 25.4 cm) rectangular vent conector is supplied.
If needed purchase 3¼" x 10" (8.3 x 25.4 cm) rectangular damper non return
valve. Accessories Part No. EXXNRVRT.

INSTALLATION INSTRUCTIONS

Horizontal discharge through wall
CUTOUT DIMENSIONS
Kitchen
5
"
1
4
"
10
1
4
Vertical discharge using 3
" x 10" duct
1
4
CUTOUT DIMENSIONS
CL
top
view
18
"
12"
7
8
3
"x10"
1
4
1
2"
1
8
"
3
8
"
3
8
1"
back
3
"x10"
1
4
view
Vertical discharge using 7" round duct
CUTOUT DIMENSIONS
CL
top
view
7"
18
"
12"
7
8
5"
2"
8
"
3
8
"
7
8
1"
back
view
3
Supplied duct
transition
Range Hood
1"
3
"
7
8
Wiring cutout
Roof Cap
1"
Elbow
9"
3
" duct
3
4
Supplied duct
transition
"
1
"
1
2
2
5"
1"
Roof Cap
adjustable
elbow
Roof
9"
Remove both
7" round duct
3
"x10" and
1
1
"
4
1
2
7" half round
7" round
knockouts
damper
for 7" duct
Range
7" round duct
Hood
5"
transition
Wall
Wall
Cap
Eave Cap
Wall
Cap
Wall