Replacing the flat fold filter
DANGER
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Accumulated dust must be transported in dust-proof
containers. Do not transfer the contents. Waste that
contains asbestos must be disposed of in accordance
with the instructions and rules for waste disposal. The
dust bag may only be disposed of by qualified staff.
WARNING
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not use the main filter element after removing it from
the device.
Permanently installed filters may only be replaced by an
expert in a suitable area (i.e. decontamination stations).
Order number for flat fold filter: 37138448
1. Turn both fastening pins of the filter cover counter-
clockwise with a screwdriver. Fastening pins are
pushed out.
Illustration R
2. Open the filter cover.
3. Remove the filter frame.
Illustration S
4. Remove the flat fold filter.
5. When removing the flat fold filter, wrap it immediate-
ly with the bag provided and seal it. Order number
for bag: 37138480
6. Dispose of used flat fold filter in dust-tight bag in ac-
cordance with statutory regulations.
7. Remove any dirt deposits from the clean air side.
8. Clean the filter frame and the supporting surface of
the filter frame with a damp cloth.
9. Fit the new flat fold filter. During insertion, ensure
that the flat fold filter is flush on all sides.
10. Insert the filter frame.
11. Close the filter cover until it audibly latches into
place.
12. Press in both fastening pins of the filter cover with a
screwdriver and tighten clockwise.
Changing the safety filter bag
DANGER
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Accumulated dust must be transported in dust-proof
containers. Do not transfer the contents. Waste that
contains asbestos must be disposed of in accordance
with the instructions and rules for waste disposal. The
dust bag may only be disposed of by qualified staff.
1. Close the suction connection, see wet vacuum
cleaning.
Illustration G
2. Unlock and remove the suction head.
3. Fold up the safety filter bag.
Illustration H
4. Take off the protective film and close the ventilation
hole with a self-adhesive tab.
5. Pull the safety filter bag out towards the back.
Illustration I
6. Seal the suction connection opening of the safety fil-
ter bag tightly with closing slides.
7. Close the safety filter bag tightly with the attached
cable tie.
Illustration J
8. Remove the safety filter bag.
9. Clean the container inside with a moist cloth.
18
10. Dispose of used safety filter bag in dust-tight bag in
accordance with statutory regulations.
11. Fit the new safety filter bag.
Illustration C
12. Pull the safety filter bag over the container.
Illustration D
13. Fit and lock the suction head.
Changing the dust bag
1. Close the suction connection, see wet vacuum
cleaning.
Illustration G
2. Unlock and remove the suction head.
3. Fold up the dust bag.
Illustration K
4. Pull the dust bag opening towards the rear over the
suction hose port.
5. Seal the dust bag tightly with cable ties under the
suction connection opening and the ventilation hole.
6. Remove the dust bag.
7. Clean the container inside with a moist cloth.
8. Dispose of the dust bag in accordance with statutory
regulations.
9. Fit the new dust bag.
Illustration E
10. Pull the dust bag over the container.
11. Fit and lock the suction head.
Cleaning/replacing the cooling air filter
1. Allow the appliance to cool down.
2. Unlock the cooling air flaps with a screwdriver and
fold them out.
Illustration T
3. Clean (vacuum, wash) or replace the cooling air fil-
ter.
4. Fold the cooling air flaps in and latch it into place.
Cleaning the electrodes
1. Unlock and remove the suction head.
2. Clean the electrodes with a brush.
3. Fit and lock the suction head.

Troubleshooting guide

DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Note
The device must be switched off immediately if a mal-
function occurs (e.g. filter breakage). The malfunction
must be eliminated before switching the device on
again.
Suction turbine does not start up
1. Check the socket and the power supply fuse.
2. Check the mains cable, mains plug, electrodes and
power socket on the device.
3. Switch on the device.
Suction turbine switches off
1. Empty the container.
2. Fit the new flat fold filter.
Suction turbine does not switch on again after emp-
tying the container
1. Switch off the device and wait for 5 seconds. Switch
on the device.
2. Clean the electrodes with a brush.
English