Reverse Operation; Bit Replacement; Nosepiece Replacement - Senco DURASPIN DS530 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REVERSE OPERATION

To operate tool in reverse for removal of screws (refer to Figure 1):
1. Flip the forward/reverse switch on the tool to reverse rotation.
2. Rotate the clamp on the attachment to the unlock position.
3. Slide the attachment off the tool to expose the bit.
4. Insert bit into screw and apply/maintain pressure to engage clutch.
5. Pull trigger until screw is completely disengaged.

bIT REPlACEMENT

Due to wear or damage, the bit will need to be replaced periodically or when changing screw recess type.
CAUTION
Remove battery or unplug tool before attempting to replace the bit.
1. Turn the clamp on the attachment to the unlock position.
2. Slide the attachment off the tool to expose the bit.
3. Remove bit per tool manufacturer's instructions
4. Insert the new bit per tool manufacturer's instructions.
5. Install attachment and rotate clamp to lock position.

NOSEPIECE REPlACEMENT

TOOl USE
1. Remove battery or unplug the tool before changing the
nosepiece.
2. Remove retention screw.
3. Set the nosepiece on the longest setting possible.
4. Depress the screw selector pin until it is completely de-
pressed. It will be necessary to use a screw or thin object to
depress to this depth.
5. While holding the pin in this position, slide the nosepiece
forward and off the slide body.
6. Install the new nosepiece.
7. Replace the nosepiece retention screw ensuring it is seated
snug against the slide body.
8. Check for proper fastener length setting (see "Adjusting for
Fastener length" above).