Assembly

5.1
Installation position
No restrictions regarding the installation position.
Preferred position: vertical position of the stem (lever/actuator on top)
5.2
Fitting Notice
Use suitable tools.
Allen keys of sizes 6, 8, 10, 14, 19;
Open-ended spanners;
Torque wrench;
TIG welding machine;
Oxy-fuel welding machine;
Clean tools before fitting.
Use suitable transport and lifting equipment for installation.
Open the packaging immediately before installation. Free of oil and grease for oxygen (O
Valves for oxygen are permanently marked with "O
Take note of the HEROSE information sheet "O2 instructions".
Only install the valve if the maximum working pressure and operating conditions of the plant
correspond to the marking on the valve.
Remove protective caps or covers before mounting.
Inspect the valve for contamination and damage.
DO NOT install a damaged or dirty valve.
Avoid damaging the connections.
The sealing surfaces must remain clean and intact.
Seal the valve with suitable seals.
No sealant (sealing tape, liquid sealing) may enter the valve.
Respect the suitability for use with O
Connect pipelines in a force-free and torque-free manner.
Stress-free mounting.
To ensure trouble-free operation, impermissible static, thermal or dynamic stresses must not be
transmitted to the valve. Observe reaction forces.
Temperature-dependent changes in length in the pipework system must be compensated with
expansion joints.
The valve is supported by the pipework system.
Detailed user information is enclosed for valves with power actuators and attachments with
safety function (sensor, switch, solenoid valve, etc.).
The valve must be protected against dirt and damage during construction work.
Remove any transport locks such as blocking bushing (optional).
Check the leak-tightness.