Product Description; Assembly And Use; Authorization Levels/Password - Abicor Binzel EWR 2 Manual De Instrucciones Original

Sistema de gestión de gases
Ocultar thumbs Ver también para EWR 2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EWR 2/EWR 2 Net

4 Product description

4.1 Assembly and use

Fig. 2
A Gas supply
B EWR 2 Net
C Slots for mounting (4 pcs.)
D Welding power source
A
The device is an electronic gas management system with a closed loop gas system. The shielding gas flow
during the welding process is optimized in terms of gas consumption and process stability, and is regulated
dependent on the welding current. A measurement shunt (F) reads the present welding current, and the
EWR 2/EWR 2 Net (B) regulates the gas flow rate via a characteristic curve that has been set as required.
This allows regulation of the gas pre-flow and post-flow periods and gas savings at the start of the process,
during welding pauses, and at the end of the process. This device consists of a housing with display and
arrow buttons, as well as a status LED. It also has a proportional valve and pressure sensors. The EWR 2 Net
device version has a measurement shunt interface, a CANopen interface, and an Ethernet interface.
 15 Shunt types on page EN-27

4.2 Authorization levels/password

The device is preset with factory settings at the time of delivery. Once the power supply is established, the
device always starts at the "User" authorization level. To change the factory settings, you require
authorization rights at the "Setter" level and must enter the following password, which has been set by the
factory: <1054>. The password can be changed via the service software at the "Setter" authorization level.
The authorization level is set by a higher authorization level to "User" if no button is pressed after 5 minutes
(timeout mechanism).
The following authorization levels exist:
User
Setter
Service
Assembly and use
B
G
Can read all data and values.
Can read and edit all data and values.
Can read and edit all data and values, can use additional functions for calibration and
change the password.
4 Product description
E Wire feeder
F Measurement shunt
G Power supply
C
D
F
E
EN - 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ewr 2 net

Tabla de contenido