4 Product description
4.3 Control elements and connections
Fig. 3
A Connection for jack plug
B <On/Bypass> button/
<ESC> button
C LED status indication
D Arrow buttons (4×)
* Available only with EWR 2 Net version
Tab. 2
Pos. Name
(B)
(C)
(D)
EN - 10
Control elements and connections
E <OK> button
F Gas discharge line connection
(connecting piece 6 mm)
G Ethernet connection*
H CANopen connection*
A
B
C
L
K
Control elements
Function
<On/Bypass>
Pressing the <On/Bypass> button for a minimum of 2 seconds switches
button/<ESC> button
the regulation function on or off. If the <On/Bypass> button is pressed
only briefly, it closes the menu without saving (similar to the ESC button).
LED status indication
The following displays can occur:
LED illuminates green:
— Device is switched on
— Shielding gas is regulated
LED illuminates red:
— Regulation function is switched off
— "Bypass" appears in the display
— Shielding gas is not regulated
LED illuminates alternating green and orange:
— Device is switched on
— Error message, fault is present
LED illuminates alternating red and orange:
— Regulation function is switched off
— Error message, fault is present
LED illuminates orange:
— Device is not ready for use
— Erroneous calibration data
— Have the device recalibrated by an ABICOR BINZEL service technician
11 Faults and troubleshooting on page EN-22
Arrow buttons
Use the arrow buttons <▲▼> to change the settings (values) in the menu
options. The <▲> button is also the Back button at the superior menu level.
The arrow buttons <◄ ►> can be used to switch between different actual
value displays and between menu items within the current menu level.
I Measurement shunt connection
J Power IN connection
K Gas supply line connection
(connecting piece 6 mm)
L Display
D
J
I
H
G
F
EWR 2/EWR 2 Net
E