CLOSES AGAIN
3
AFTER THE
PHOTOCELL
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
MASTER/
7
SLAVE
To carry out the memorization, leave DIP SWITCH 7 on OFF.
WITH LIMIT
SWITCHES:
SELECTION
TOWARDS OPENING
8
WITHOUT LIMIT
SWITCHES:
BACK JUMP
To change the position of Dip 8, the power must be disconnected. Once modified, rerun
the SetUp of the stroke
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
On
On
On
Off
Off
On
Off
Off
IMPORTANT: the type of automation and its parameters are set during the programming
of the stroke ONLY the first time the procedure is carried out (led DL2 flashing red/green
alternately). To change the type it is necessary to perform a "FACTORY RESET" before
starting a new setup procedure.
6. MEMORIZATION PROCEDURE OF THE STROKE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations and check:
- The Input connections: all green DL5, DL6, DL7, DL8 must be on steady.
- The mechanical stops of the automation must be installed and adjusted both in opening and
in closing [see motor instructions].
after the photocell is activated (input 7 - 9), the automation closes automat-
On
ically after 5 seconds.
Off function off.
the automation ignores the closure command during opening and auto-close
On
time
Off the automation responds as established by dip switch No. 2.
On the pre-flashing function is enabled.
Off the pre-flashing function is disabled.
On the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-COMM
On
instructions).
enables the standard operation (single motor) or SLAVE mode in the mas-
Off
ter/slave configuration (see T-COMM instructions).
On operation for gate with opening to the right (gearmotor side);
Off operation for gate with opening to the left (gearmotor side);
once the mechanical stop of the closing maneuver is reached, the automa-
On
tion makes a slight movement in the opposite direction to avoid jamming
between the rack and the pinion.
Off function deactivated
Dip 11 Automation
Off
T-ONE10B For gates up to 400 kg
Off
T-ONE10B For gates from 600 to 1000 kg
Off
T-ONE8BR (24v)
Off
MASTER-R (24V Opening speed = Closing speed)
On
MASTER18QR
On
MASTER-R (24V)
On
T-ONE8BR (24V Opening speed = Closing speed)
On
CANTILEVER TONE10B (heavy)
23