Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution; accuracy ±1 °C at 20 °C
Temperature setting: 7 °C to 30 °C in 0.2 °C increments
Differential setting: 0.1; 0.2; 0.5; 1 °C
Operating temperature: 0 °C to 40 °C
Storage temperature: -10 °C to 60 °C
Unit interconnection: via 868 MHz radio signal, max. 25 mW e.r.p.
Pairing capacity: max. 6 receivers
Transmitter unit range: up to 100 m in an open space
Power supply:
Control unit (transmitter) 2× 1.5 V type AA (LR6) batteries
Switching unit (receiver) 230 V AC/50 Hz
Dimensions and weight:
Control unit: 23 × 97 × 122 mm; 143 g
Switching unit: 37 × 115 × 91 mm; 150 g
Control (Portable) Unit
(see Fig. 1)
1 – day of the week
2 – clock
3 – comfort mode
4 – economy mode
5 – manual control
6 – programme preset
7 – comfort/economy mode switch
8 – UP button
9 – change clock
10 – change programme
11 – wireless communication icon
Removing the Rear Cover of the Control Unit
(see Fig. 2)
1. Use a screwdriver to press and hold the inner lock.
2. Remove THE front cover.
Switching Unit
(see Fig. 3)
1 – main switch
2 – pairing button
3 – LED indicators
12 – set temperature
13 – frost indication
14 – operation status icon
15 – battery status indication
16 – current room temperature
17 – day profile
18 – DOWN button
19 – change temperature
20 – illuminate screen
21 – RESET
4