Cautions - Inogen Rove 6 Manual Del Usuario

Ocultar thumbs Ver también para Rove 6:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 303
parts and accessories not mentioned in these
instructions for use.
• It is the responsibility of the patient to periodi-
cally check the battery and replace as necessary
per these instructions for use. Inogen assumes
no liability for persons choosing not to adhere to
manufacturer recommendations.
• To ensure you are receiving the therapeutic
amount of oxygen according to your medical
condition, the device must (1) be used only after
one or more settings have been individually
determined or prescribed for you at your specific
activity levels, (2) be used with the specific com-
bination of parts and accessories that are in line
with the specification of the concentrator manu-
facturer and that were used while your settings
were determined.
• The settings of other models or brands of oxygen
therapy equipment may not correspond with the
settings of this device.
• The settings of this device may not correspond
with the settings for devices that provide a con-
tinuous flow oxygen.
• Use of this device at an altitude above 3,048 m
(10,000 ft) or outside the temperature range of
5 – 40°C (41 – 104° F)or a relative humidity above
95% is expected to adversely affect the flowrate
and the percentage of oxygen and consequently
the quality of the oxygen therapy. Use of this
device immediately after storage in tempera-
tures beyond the allowable operating range may
adversely affect operation of the device until the
temperature returns to the allowable operating
range. Wind or strong drafts can adversely affect
the accurate delivery of oxygen therapy.
• If the device fails, it will cause a return to your
previous condition prior to starting oxygen ther-
apy. This state will be different for each individ-
ual patient.
• The proper placement and positioning of the
nasal cannula in the nose is critical to the con-
sistent operation of this equipment.
• Do not use this device in conjunction with a
humidifier, nebulizer, or CPAP, or in parallel
or series with other oxygen concentrators or
©2022 Inogen, Inc. All rights reserved.
oxygen therapy devices. Doing so may impair the
performance and could damage the equipment.
3.2 CAUTION!
Risk of minor injury or discomfort
• The device, parts and accessories are specified for
use at flow rates between setting 1 and setting 6.
• Incompatible parts and accessories can result in
degraded performance or damage and may void
your warranty.
• The device is designed to provide a flow of high
purity oxygen. An advisory alert, "Oxygen Low",
will inform you if oxygen concentration drops. If
alarm persists, contact your equipment provider.
• The oxygen flow setting must be determined and
recorded for each patient individually by the pre-
scriber, including the configuration of the device,
its parts and the accessories. It is the responsi-
bility of the patient to periodically reassess the
setting(s) of the therapy for effectiveness.
• Do not modify the device. Any modifications
performed on the equipment may impair perfor-
mance or damage equipment and will void your
warranty unless indicated or instructed to do so.
• Do not use oil, grease, or petroleum-based prod-
ucts on or near the device or its accessories.
• Do not use lubricants on the device or its
accessories.
• Do not obstruct air intake or exhaust when
operating the device. Blocking air circulation
or placing close to a heat source may lead to
internal heat buildup and shutdown or damage to
the concentrator. In the event of changes to the
performance of the device, please refer to the
troubleshooting section of this document.
• Do not operate the device without the particle
filter in place. Particles drawn into the system
may damage the equipment.
• Do not wrap cords around power supply for
storage. Do not drive, drag or place objects over
cord. Doing so may lead to damaged cords and a
failure to provide power to the concentrator.
• Do not use the DC power cord with a cigarette
Page 8 of 356
96-12100-06-01-A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Is-501Io-501

Tabla de contenido