Remove the lid from the control
module.
Connect the light switch to
connection b.
Secure the cable with the strain relief
provided.
Connection a must be bridged.
Close and screw on the lid of the
control module.
If earthing cannot be ensured using
the fixing screws, connect the
earthing wire provided.
en - Operating and installation instructions
After all components have been
installed, carry out an electrical
safety check in accordance with
local regulations (e.g. VDE 0701-1 in
Germany).
Connecting the potential-free
contact
The potential-free connection can be
used to control other appliances
depending on the switch status of the
cooker hood fan.
When connecting ventilation
appliances, the advice of a building
regulations inspector must be
sought.
The contact does not supply a defined
voltage (potential-free). This means that
the connection is suitable for universal
application. The maximum switching
capacity of the contact is 230 V/2 (1) A.
The contact closes when the On/Off
button for the cooker hood is switched
on. The indicator light for the On/Off
button and the indicator light for the
second fan setting will come on.
Remove the lid from the control
module.
13