OPERATE PUMP (A)
Check the Hydraulic Fluid Level, following the
instructions in the Cleaning and Maintenance section.
Determine which direction the frame needs to be bent.
Remove any obstructions that could be damaged or are
in the way.
Position the Pump Unit on a stable, flat and level surface.
Close the release valve by turning it clockwise until it is
firmly closed. Pump Handle to apply pressure.
Turn the Release Valve counter-clockwise to release the
pressure.
Note: The Pump Unit may be positioned horizontally or
vertically. When using the Hydraulic Pump (A) in a
vertical position, always keep the Hose (21) end of the
Hydraulic Unit downward.
OPERATE RAM (B)
1. Connect the appropriate Base (3, 4, 7) to the stationary side of the Ram (B), and connect the
appropriate head to the pushing end of the Ram.
2. Note: When repairing larger body panel dents such as a dented door, fender or quarter-panel use
the Rubber Head (10) on the pushing end.
3. lf using the Flange Base (4) or Flange Head (5): Thread the Flange Base onto the Ram
completely and align the Flange Head to it. The Flange Base and Flange Head must only be
used together to prevent off-center load.
4. Position the Ram (B) so that the Base is resting against a frame member opposite the damaged
area. lt must also be in line with the direction in which the damaged area needs tobe pushed. The
vehicle body part must be stronger than the area to be bent or it may be damaged. A block of
wood or a towel may be used to protect the body part.
5. Aim the pushing end towards the area that needs to be repaired, and slowly apply pressure with
the Pump (A).
Note: To prevent damage, do not overextend the Ram.
OPERATE SPREADER (C)
1. Place the Spreader (C) so that the hinged (pushing) arm is resting against the part to be moved
and the stationary arm is resting against a non-movable base.
2. Carefully hold the Spreader in position and apply pressure with the Pump (A).