Zone 1
Zone 4
RISKS
Zone 1
Risk of crushing when
closing
Zone 2
Risk of trapping and cut-
ting on the apron surface
Zone 3
Risk of crushing with an
adjoining fixed section
upon opening
Zone 4
Risk of trapping and
crushing between the
roller rails and bearings
Zone 5
Risk of catching and
crushing at the pinion/
rack connection
No protection is required if the gate has hold-down
control or if the danger zone is more than 2.5 m
above ground or any other permanent access level.
6
Zone 3
Zone 2
Zone 5
SOLUTIONS
Obstacle detection built
into the motorisation.
Obstacle detection must
be confirmed as being
compliant with Appendix
A of standard EN 12 453.
For operation with auto-
matic
closing,
photoelectric cells.
Obstacle detection built
into the motorisation.
Obstacle detection must
be confirmed as being
compliant with Appendix
A of standard EN 12 453.
Eliminate any gap ≥ 20
mm.
Obstacle detection built
into the motorisation.
Obstacle detection must
be confirmed as being
compliant with Appendix
A of standard EN 12 453.
Protection by safety dis-
tances
[}
p.6].
Eliminate all sharp edges
on the guide rails.
Eliminate any gap ≥ 8 mm
between the rails and the
bearings.
Eliminate any gap ≥ 8 mm
between the pinion and
the rack.
Illustration 1: Safety distance
1.5
Electrical installation
DANGER
The installation of the power supply must
comply with the standards in force in the
country in which the motorisation is installed,
and must be carried out by qualified person-
nel.
The power line must be exclusively reserved
for the motorisation, and equipped with pro-
tection comprising:
a 10 A fuse or breaker,
install
a differential type device (30 mA).
An all-pole power supply cut-off device must
be provided. The switches provided to ensure
a cut-out of all poles on fixed appliances must
be connected to the power supply terminals
and there must be a separation between the
contacts on all poles to ensure complete dis-
connection in conditions where category III
high impulse voltage is present.
Low-voltage cables subject to inclement
weather must be at least H07RN-F.
It is recommended that you fit a lightning ar-
rester (mandatory maximum residual voltage
2 kV).
Cable run
DANGER
Underground cables must be equipped with a
protective sheath with a sufficient diameter to
insert the motor cable and the accessories
cables.
For overground cables, use a cable duct that will
withstand the weight of the vehicles (Ref. 2400484).
1.6
Safety instructions relating to installation
DANGER
Do not connect the motorisation to a power
source before installation is complete.
WARNING
Modifying any of the components in this kit or
using additional components not recommen-
ded in this manual is strictly prohibited.
Monitor the gate as it moves and keep people away
from it until installation is complete.
Do not use adhesive to mount the motorisation.