DETECTION RANGE
The detection range of the infrared sensor is set at the factory and does not need further
adjustment.
*Measure on a 300mm x 300mm square white board.
*The Detection Range diagram below is for illustrative purposes.
TET1GB, TET1LB(X), TET1UB(X)
PRECAUTION
DO NOT place the infrared sensor of one
flush valve in line with sensor of another
Flush Valve.
Another infrared sensor.
Infrared sensor of the automatic
Flush Valve.
NOTE: In some cases, the valve may not
detect a user if the toilet seat is left in
an upright position. This can be caused
by the rough-in dimension or gap of the
open front commercial seat. Please
lower the seat or contact a plumbing
contractor to change the height of the
valve.
The sensor can have trouble detecting
users wearing black clothes in some
conditions.
Max 19-11/16"
(Max 500 mm)
TET6LB, TET6UB, TET6GB
15°
PRECAUTION
DO NOT place the infrared sensor in
front of a mirror, stainless steel wall, or
other highly reflective surface.
Mirror, stainless steel wall or other
Infrared sensor of the automatic
Flush Valve.
- 16 -
Max 21-1/4"
(Max 550 mm)
Control stop
Use chrome plated elbow
to adjust the height of
TOTO EcoPower Flush
Valve from the fixture.
Elbow
20°