Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
The hot and cold supplies must be of equal pressures.

Installation Instructions

The fitting must be installed, flushed and tested after the valid norms.
The mesh washers must be installed to protect against incoming dirt by pipework.
Incoming dirt can impair the function and/or lead to damages on functional
parts of the fixture; HansGrohe will not be held liable for resulting damages.
The installation dimensions stated in this installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case you will have to attend to the minimum height of
2300 mm from shower tray floor, and alter all the required measurements as
necessary.
Where the contractor mounts the product, he should ensure that the entire area
of the wall to which the mounting plate is to be fitted, is flat (no projecting joints
or tiles sticking out), that the structure of the wall is suitable for the installation
of the product and has no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall constructions the manufacturer's
indications of the dowel manufacturer have to be taken into account.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Connections:
anti-pollution function
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Safety stop button not operating
Shower drips continuously
4
max. 1 MPa
0,2 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
cold right - hot left
Cause
- Supply pressure inadequate
- Filters are dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- Temperature regulator dirty or calcified
- Spring defective
- Button calcified
- Dirt or sedimentation on valve seat, shut-off unit
damaged
Assembly see page 32
English

Symbol description

Do not use silicone containing acetic acid!
Safety Function (see page 33)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 33)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Dimensions (see page 31)

Flow diagram

(see page 31)
overhead shower
hand shower
body showers
overhead shower + body showers
Operation (see page 34)
Maintenance (see page 35)
The non return valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
Cleaning (see page 34)
and enclosed brochure
Spare parts (see page 36)
Test certificate (see page 34)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Cleaning the filter in the water connection and at the
thermostat cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Clean temperature regulator, exchange if necessary
- Clean spring and/or button, exchange if necessary
- Clean or exchange shut-off unit

Publicidad