6
Commissioning
6.1
Alignment
6.2
Sensing range
8025390.1CGF/2021-07-13 | SICK
Subject to change without notice
Align the sender with the receiver. Select the position so that the red emitted light beam
hits the receiver. Tip: Use white paper or a reflector as an alignment aid. The sender
must have a clear view of the receiver, with no object in the path of the beam [see
figure
4]. You must ensure that the optical openings (front screen) of the sensors are
completely clear.
Figure 4: Alignment
Check the application conditions: Adjust the distance between the sensor and the
reflector according to the relevant diagram [see
operating reserve).
When mounting multiple through-beam photoelectric sensors next each other, swap
the arrangement of the sender (GS6L) and receiver (GE6L) for every second pair.
Also maintain a sufficiently large distance between the pairs based on the light spot
diameter of the sender (GS6L). This will prevent any mutual interference from arising
[see
figure
2].
Check the function as described in
described in
table
3, check the application conditions.
OPERATING INSTRUCTION
figure
5] (x = sensing range, y =
table
3. If the switching output fails to behave as
O P E R A T I N G I N S T R U C T I O N | GSE6L