Descargar Imprimir esta página

SICK G6L Instrucciones De Operación página 25

Ocultar thumbs Ver también para G6L:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Tabelle 3: Output function
GE6L
-Px1xx
-Px2xx
-Px5xx
-Px6xx
L.ON, PNP: Q (≤ 100 mA)
-Px1xx
-Px2xx
-Px3xx
-Px4xx
D.ON, PNP: Q (≤ 100 mA)
-Nx1xx
-Nx2xx
-Nx5xx
-Nx6xx
L.ON, NPN Open Collector Q (≤ 100 mA)
-Nx1xx
-Nx2xx
-Nx3xx
-Nx4xx
D.ON, NPN Open Collector Q (≤ 100 mA)
5.1
Hinweise zur UL Zulassung
8025390.1CGF/2021-07-13 | SICK
Irrtümer und Änderungen vorbehalten
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a)
max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b)
100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1