electRIcal PoweR ReQuIReMents
electRIcal wIRIng
Refer to the air compressor's serial label for the unit's voltage and amperage
requirements.
use a dedicated circuit
for best performance and reliable starting, the air compressor must be
plugged into a dedicated circuit, as close as possible to the fusebox
or circuit breaker. The compressor will use the full capacity of a typical 15
amp household circuit. If any other electrical devices are drawing from the
compressor's circuit, the compressor may fail to start. Low voltage or an
overloaded circuit can result in sluggish starting that causes the motor overload
protection system or circuit breaker to trip, especially in cold conditions.
note: A circuit breaker is recommended. If the air compressor is connected to
a circuit protected by a fuse, use dual element time delay fuses (Buss Fusetron
type "T" only).
eXtensIon coRDs
note: Avoid use of extension cords.
For optimum performance, plug the compressor power cord directly into
a grounded wall socket. Do not use an extension cord unless absolutely
necessary. Instead, use a longer air hose to reach the area where the air is
needed.
If use of an extension cord cannot be avoided, the cord should be no longer
than 50 feet and be a minimum wire size of 12 gauge (AWG). Do not use a 16 or
14 gauge extension cord.
Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot
receptacle that will accept the plug on the product. Make sure your extension
cord is in good condition. An undersized cord will cause a drop in line voltage,
resulting in loss of power and overheating. The smaller the gauge number, the
heavier the cord.
gRounDIng InstRuctIons
foR coRD-connecteD MoDels:
This product should be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
This product is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded in accordance with all local codes and
ordinance.
note: not all units shipped with power cord.