4.8 SUMMARY INFORMATION
4.8.1 Data from welding machine to robot
WORD
BYTE
BIT
N°
N°
MASK
0
0 (MSB)
0x01
0x02
0x04
0x08
0x10
0x20
0x40
0x80
1 (LSB)
-
1
2 (MSB)
-
3 (LSB)
2
4 (MSB)
-
5 (LSB)
3
6 (MSB)
-
7 (LSB)
4
8 (MSB)
-
9 (LSB)
5
10 (MSB) 0x01
0x02
0x04
0x08
0x10
0x20
0x40
0x80
11 (LSB)
0x01
0x02
0x04
0x08
0x10
0x20
0x40
0x80
6
12 (MSB) 0x01
0x02
0x04
0x08
0x10
0x20
0x40
0x80
13 (LSB)
-
7
14 (MSB)
-
15 (LSB)
-
8
16 (MSB)
-
17 (LSB)
-
68
PARAMETER
NOTES
ARC ON
0=arc off, 1=arc on
WELDING TOOL READY
0=welding tool ready for use, 1=system in alarm status
WIRE STICKED
0=wire not glued, 1=wire glued
NOT AVAILABLE
-
GAS PRESENCE
0="no gas" alarm, 1=gas present
WATER PRESENCE
0=water presence, 1="no water" alarm
PIECE PRESENCE
0=piece not touched, 1=piece touched
SAFETY LIMITS
0=safety limits alarm active, 1=no active alarm
ALARM QUEUE
Consult the section "Alarm queue - Genesis ..."
0-255
AO1
Default: welding current
1 ANALOG OUTPUT
0-65535
AO2
Default: welding voltage
2 ANALOG OUTPUT
0-65535
AO3
Default: gas flow
3 ANALOG OUTPUT
0-65535
AO4
Default: wire speed
4 ANALOG OUTPUT
0-65535
ANTISHOCK
0=antishock alarm active, 1=system operating normally
NOT USED
-
HEART BIT
Confirmation signal active communication. F=0.5 Hz
NOT USED
-
1 DIGITAL OUTPUT
Configurable
(Consult "Genesis...repair manual)
2 DIGITAL OUTPUT
Configurable
(Consult "Genesis...repair manual)
NOT USED
-
NOT USED
-
1 DIGITAL OUTPUT
see byte 10, bit mask 0x10
2 DIGITAL OUTPUT
see byte 10, bit mask 0x20
3 DIGITAL OUTPUT
0= piece not touched, 1= piece touched
4 DIGITAL OUTPUT
0=antishock alarm active, 1=system operating normally
5 DIGITAL OUTPUT
-
6 DIGITAL OUTPUT
-
7 DIGITAL OUTPUT
-
8 DIGITAL OUTPUT
-
1 DIGITAL INPUT
Emergency
0=alarm active, 1=alarm inactive
2 DIGITAL INPUT
Maintenance
0=welding tool is ready for use, 1=system in alarm sta-
tus
3 DIGITAL INPUT
-
4 DIGITAL INPUT
-
5 DIGITAL INPUT
-
6 DIGITAL INPUT
-
7 DIGITAL INPUT
-
8 DIGITAL INPUT
Wire end device
0=wire end alarm
1=welding tool is ready for use
NON USED
-
AO5
Motor current 1
5 ANALOG OUTPUT
0-65535
AO6
Motor wire speed 2
6 ANALOG OUTPUT
0-65535