7.3 EXTRAORDINARY MAINTENANCE (INTENDED FOR QUALIFIED PERSONNEL)
These operations are reserved exclusively for authorised qualified personnel. FRIGOMAT
S.r.l. will not be held liable for damage to objects or harm to persons which occur due to
failure to comply with the above.
HEATER MEB² BOARD PROGRAMMING
Refer to the following instructions to program the circuit board:
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
1. Ensure the lid is assembled in machine and in
closing position.
2. Power the machine.
3. With the machine at STOP, press the "STOP" and
"MIXING" keys simultaneously and release them
only after the password identification screen
appears (fig.1).
4. Press the "MIXING(▲)", "AUTOMATIC 85° (▼)"
and "SEMI-AUTOMATIC (◄►)" keys to enter the
password and then confirm it (fig.2). If you do not
know
the
password,
assistance service.
5. When the password has been accepted, the screen
accesses the list of programming steps directly. The
first
programming
automatically
6. If you do not wish to change the value of the
selected step, press "MIXING (▲)" to directly
access the following step (Fig. 3).
7. If, instead, you wish to change the selected step,
press ""SEMI-AUTOMATIC (◄►)" to access the
parameters relative to the same step, and
subsequently press "MIXING (▲)" or "AUTOMATIC
85° (▼)" to increase or decrease the value.
Subsequently,
press
(◄►)" key to confirm the data (fig.4).
8. To exit programming and save the changes press
the "STOP" key (fig.5).
contact
the
Frigomat
step
P01
is
selected
the
"SEMI-AUTOMATIC
ENGLISH - 24