8. TROUBLESHOOTING INSTRUCTIONS
8.1 MANAGEMENT OF HEATER ALARMS
MESSAGE
TER
DIS
TEv Int
TEv cor
TEf Int
TEf cor
DESCRIPTION
A circuit breaker or the transformer fuse
has intervened.
The buzzer emits an intermittent acoustic
signal.
Communication between the board and
the display interrupted.
The tank probe is interrupted.
The buzzer emits an intermittent acoustic
signal.
The tank probe is in short-circuit.
The buzzer emits an intermittent acoustic
signal.
The fluid probe is interrupted.
The buzzer emits an intermittent acoustic
signal.
The fluid probe is in short-circuit.
The buzzer emits an intermittent acoustic
signal.
REMEDIES
Wait a few minutes and then
press STOP to restore machine
operation.
If the alarm continues, contact
the technician.
Contact the technician.
Contact the technician to check
and replace the faulty probe.
Contact the technician to check
and replace the faulty probe.
Contact the technician to check
and replace the faulty probe.
Contact the technician to check
and replace the faulty probe.
ENGLISH - 26