11 Using the software without connecting to a PC
11.1 Free Page for measuring the opacity
Select the item referred to the free page.
Confirm using the key ().
The free page displays:
-
% opacity value
-
opacity value expressed in m
-
maximum opacity value in the last 5s (expressed in m
-
Tsm exhaust gas temperature
-
Toilo engine oil temperature
-
Engine rpm
It is possible to access the following functions from this page by pressing F key:
-
Free acceleration
-
Automatic zeroing, to perform cell zeroing
-
Rpm division
-
Printing free page values
11.2 Free acceleration
Procedure starts from the free page
Press F key.
Select the item referred to the free acceleration.
Confirm using the key ().
After having selected the function go to the vehicle,
get ready to accelerate and press a key.
The program waits for acceleration, which is
recognised thanks to
one of the following methods:
- opacity variation
- engine rpm variation
- exhaust gas temperature variation
- the user presses a key (manual confirmation
of the acceleration using the key )
- maximum waiting time is over
When acceleration is detected, data acquisition
phase begins.
At the end of the acquisition phase the vehicle is
to be decelerated. Deceleration
<Exhaust Gas Analysis>
►Free Page
Official Proc.
-1
►Free acceleration
Automatic zeroing
Rpm division
...
Get ready to
Accelerate
Press a key
TO ACCELERATE:
1050
DATA ACQUISITION
IN PROGRESS
DECELERARE
25
-1
)