mentioned on the vehicle plate.
To continue press the confirmation key ().
If necessary, edit the vehicle maximum power rpm value.
This value
is usually available on the vehicle logbook.
To continue press the confirmation key ().
If necessary, edit the engine oil temperature lower limit
to take into account the conditioned vehicle before the test.
To end limit editing phase press confirmation key ().
To display and if necessary, edit environmental temperature, pressure
and humidity values select item "Environmental Data".
If necessary, edit environmental temperature.
To continue press the confirmation key ().
If necessary, edit environmental pressure.
To continue press the confirmation key ().
If necessary, edit environmental humidity.
To end environmental data editing phase press confirmation
key ().
To start the test, select item "Start test" and press confirmation
key ().
The vehicle conditioning phase follows, with engine oil
temperature measurement.
If the measured temperature value reaches or exceeds the limit, the
program continues automatically
To enter the oil temperature value manually press key ().
The print report highlights the data that have been entered manually.
Before the opacity values are displayed, the cell values
are reset (see para. Error. The reference source has not been
found.).
To check that all values are correct, the main measured values
are displayed.
A new cell zeroing procedure can be performed by pressing function
key F (see para. Error. The reference source has not been found).
and if necessary, edit the engine rpm divisor (see para. 11.1.5).
To start acceleration measurement phase press key. ().
The SW automatically manages the acceleration sequence.
Follow displayed instructions.
Acceleration is automatically detected. However, it is possible to
force opacity value acquisition start during acceleration
by pressing key ().
29
Opacity limit
3.00 /m
<123>
Max power rpm value
4500 RPM
<123>
Min. temp. Limit 80 °C
Test start
Edit
►Environmental Data
Limits
<123>
Temperature [°C]
19
<123>
Pressure[kPa]
101.2
<123>
Humidity[%]
30
►Start test
Edit Environmental Data
Limits
Vehicle Conditioning
Ins. Oil probe
Temp: 76 °C
Min 80 °C
(Reset)
K=0.00 [1/m] Tsm=25°C
RPM=1025 RPM
Limit: 3.0 [1/m]
() Start Procedure
ACCELERATE
1020