IO-Link Data Dictionary
21.10.01.00065/02
Setpoint H2
204
0x00CC
205
0x00CD
Hysteresis h2
206
0x00CE
Duration automatic blow
207
0x00CF
Permissible evacuation time
Permissible leakage rate
208
0x00D0
Production Setup - Profile P3
220
0x00DC
Air saving function
221
0x00DD
Disable continuous suction
Setpoint H1
222
0x00DE
223
0x00DF
Hysteresis h1
224
0x00E0
Setpoint H2
225
0x00E1
Hysteresis h2
Duration automatic blow
226
0x00E2
227
0x00E3
Permissible evacuation time
228
0x00E4
Permissible leakage rate
Commands
System command
2
0x0002
Calibrate vacuum sensor
120
0x0078 CAL
Restore to factory defaults
123
0x007B rES
J. Schmalz GmbH
2 bytes
(H1-h1 >= H2 >= (h2+2)
rw
2 bytes
(H2-2) >= h2 >= 10
rw
2 bytes
100 - 9999
rw
2 bytes
0, 10 - 9999
rw
2 bytes
1 - 999
rw
1 byte
0 - 2
rw
1 byte
0 - 1
rw
2 bytes
998 >= H1 >= (H2+h1)
rw
2 bytes
(H1-H2 >= h1 > 10
rw
2 bytes
(H1-h1 >= H2 >= (h2+2)
rw
2 bytes
(H2-2) >= h2 >= 10
rw
2 bytes
100 - 9999
rw
2 bytes
0, 10 - 9999
rw
2 bytes
1 - 999
rw
1 byte
wo
1 byte
1
wo
1 byte
1
wo
5 of 11
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
550
10
200
2000
250
Profile P-3
1
(selected by PD Out 0 - Profile-Set = 3)
0
750
150
550
10
200
2000
250
0x05 (dec 5): Force upload of parameter data into the master
0x82 (dec 130): Restore device parameters to factory defaults
0xA4 (dec 164): Clear diagnostic buffer
0xA5 (dec 165): Calibrate vacuum sensor
1 = Calibrate vacuum sensor
(can also be executed by switching PD Out 0 Bits 2 and 3 simultaneously
from 0 to 1)
1 = Restore to factory defaults
SCPSi series
29.08.2014
SCPSi Data Dictionary