WARN IN G
Fire and/ or Electrical Shock Hazard
Do not operate w ith a clogged exhaust
filter or w ithout the exhaust filter
installed. Do not operate w ithout filter
cover installed.
EXHAUST FILTER - HEPA MEDIA
The exhaust filter cartridge must be
replaced when dirty. Replace the filter
when the entire surface area is covered
evenly. The filter CAN N OT be w ashed as it
w ill lose its dust trapping ability.
N OTE: See REPLACEMEN T PARTS for part
number and purchase details (page 6).
1. Push latch up to release the exhaust
filter cover from slot in canister.
Exhaust Filter
Cover
Latch
2. Pull filter cover and outward to remove it
from filter chamber in the canister.
3. Remove the exhaust filter cartridge from
the filter cover.
Exhaust
Filter
EXHAUST FILTER CHAN GIN G
4. Insert the new exhaust filter cartridge
into the filter cover with the rubber seal
upward.
5. To replace the exhaust filter cover, insert
the two tabs on the cover into the slots
at the top of the filter chamber.
Tabs
6. Rotate filter cover down until it snaps
into place.