Descargar Imprimir esta página

SICK HTE18 Manual De Instrucciones página 32

Ocultar thumbs Ver también para HTE18:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
OPERATING INSTRUCTION
1.3
Intended use
1.4
Product description
1.5
Operating and status indicators
1.6
Mounting
32
O P E R A T I N G I N S T R U C T I O N | HTE18
This product does not constitute a safety component as defined in the
NO
Machinery Directive.
2006/42/EC
SAFETY
Do not install the product in places exposed to direct UV radiation (sun‐
light) or other weather conditions.
The product must be adequately protected against moisture and contami‐
nation.
The HTE18 is an opto-electronic photoelectric proximity sensor (referred to as "sensor"
in the following) for the optical, non-contact detection of objects, animals, and persons.
If the product is used for any other purpose or modified in any way, any warranty claim
against SICK AG shall become void.
The sensor complies with the Radio Safety Requirements (EMC) for the industrial sector
(Radio Safety Class A). It may cause radio interference if used in a residential area.
2
1
3
2
3
4
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
NOTE
Note the sensor's maximum permissible tightening torque of 0.56 Nm.
Potentiometer adjustment (if
1
selected by model configuration) or
LED Indicators
Green LED: supply voltage active
2
(with IO Link, flashes when IO Link
Communication is active)
Yellow LED: status of received light
3
beam (with IO Link, when teach
mode is active)
Signal strength light bar (if selected
4
by model configuration)
8017851.1HW2/2022-11-14 | SICK
Subject to change without notice

Publicidad

loading