OPERATING INSTRUCTION
1.8.3
Setting
44
O P E R A T I N G I N S T R U C T I O N | HTE18
Table 21: % of sensing range
Operating reserve
100
10
2
1
1
0
100
200
300
(3.94)
(7.87)
(11.81)
Figure 7: Redlight
Figure 9: Description of the sensing range areas
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
Refer to graphic to check the function. If the switching output fails to behave in accord‐
ance with graphic, check application conditions. See section Fault diagnosis.
Sensor with potentiometer (without IO Link):
The sensing range is adjusted relative to the background with the potentiometer (type:
270°).
Clockwise rotation: sensing range increased; counterclockwise rotation: sensing range
reduced.
Turn the potentiometer clockwise until the yellow LED indicator lights up. When an
object is moved into the path of the beam, the yellow LED indicator must go out. If the
yellow LED indicator remains lit when an object is moved into the path of the beam,
repeat the adjustment.
Operating reserve
1,000
100
10
3
1
0
400
500
600
(15.75)
(19.67)
(23.62)
Distance in mm (inch)
Figure 8: Infraredlight
1
3
2
200
400
600
800
(7.87)
(15.75)
(23.62)
(31.50)
Distance in mm (inch)
8017851.1HW2/2022-11-14 | SICK
Subject to change without notice
1,000
(39.37)