OPERATING INSTRUCTION
1.9
Troubleshooting
46
O P E R A T I N G I N S T R U C T I O N | HTE18
Time types
Time types: HTE18 with optional On-delay or Off-Delay adjustment: t0 = no time delay,
t1 = time delay when object is detected, t2 = time delay when no object is detected.
The time setting can be selected using the potentiometer according to A.
Timer stages can be set from 0 to 2 seconds.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 22: Troubleshooting
LED/fault pattern
Yellow LED does not light up
even though the light beam is
aligned to the object and the
object is within the set sensing
range
Green LED flashes
Digital outputs not according to
graphic
Digital outputs not according to
graphic
Yellow LED flashes; if Health is
present then take note of the
corresponding output signal; if
Alarm is present then take note
of the corresponding output
signal
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
Object is in the path of the
beam, yellow LED does not
light up
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
IO-Link communication
IO-Link communication
Parameter settings made
manually, which deviate from
the standard
Sensor is still ready for oper‐
ation, but the operating con‐
ditions are not ideal/addition‐
ally with health output: power
supply interrupted
Excessive background remis‐
sion
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Remission capability of the
object is insufficient
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
-
-
Initiate a factory reset. The
digital outputs are reset to
factory settings.
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
object / Clean the optical sur‐
faces / Check sensing range
and adjust if necessary, see
figures in
section 1.8.2
/ With
health output: Check the volt‐
age supply, check all electrical
connections (cables and plug
connections).
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Increase the sensing range,
take note of the distance
between the sensor and the
background, see Figure
see
table 21, page 44
Increase the sensing range,
take note of the distance
between the sensor and the
background, see Figure
see
table 21, page 44
8017851.1HW2/2022-11-14 | SICK
Subject to change without notice