if the voltage is below nomimal (12.8V) and the program should detect obvious cell damage and will
automatically suspend charging, but the higher the cell count in parallel the more difficult it is to detect a bad
cell e.g. a 5Ah battery made with standard cylindrical cells typically has 4 series connected sets of 2 parallel
cells (4S2P configuration - total 8 cells), a 10Ah battery has 4 series connected sets of 4 parallel cells (4S4P
configuration - total 16 cells).
ALWAYS monitor the battery temperature during the first hour, then hourly there-after. If at any time the
battery is uncomfortably hot to touch or you notice any unusual signs, DISCONNECT THE CHARGER
IMMEDIATELY.
STEP 1
1
CONNECT
TO THE
BATTERY
1
Protection
BMS
RESET
Manual
Activation
6
LED #1: Confirms AC power supply to the charger.
OptiMate Lithium automatically activates and LED #1 brightens if the
connected battery voltage is at least 0.5 Volt.
2
The program proceeds directly to STEP 2.
LED #2 REVERSE POLARITY:
incorrect. The charger is electronically protected so no damage will
result, and the output will remain disabled until the connections are
corrected.
2
Charger will not proceed without user interaction.
BMS RESET:
system (BMS) that protects against deep discharge.
Bms
Bms
IMPORTANT! Before proceeding, confirm the battery is connected
3
4
correctly: Read the section on the previous page: CONNECTING
CHARGER TO THE BATTERY.
12.8V
Touch and hold on the BMS RESET button. LED #3 blinks every
12 3 4
LFP / LiFePO
second as a special BMS reset pulse is delivered.
Bms
Bms
LED# 3 turns full on when the OptiMate Lithium senses the battery
3
4
BMS has reset.
Remove finger from button. The reset pulses will automatically
12.8V
discontinue and the program will continue to STEP 3, 4 & 5.
12 3 4
LFP / LiFePO
LED #3 lights briefly and then turns off: A deep discharged battery
may not hold sufficient voltage to power its own BMS system. To
FORCE a reset, place and hold finger on BMS reset button for 10 or
more seconds, until LED# 3 remains full on.
BMS not resetting: LED #6 flashes/blinks.
1) Battery is connected in reverse polarity. Correct the connections
and try again. 2) The system powered by the battery is preventing
the pulse from being delivered. Disconnect or turn off the system and
try again. 3) The battery's BMS or the battery itself may have
suffered damage. Have the battery professionally assessed. 
More: 4) An advanced battery management system may include
thermal protection that prevents reset if the battery temperature falls
outside of the manufacturer recommended safe operating
temperature range. Check battery manufacturer's specifications.
MANUAL CHARGE ACTIVATION: Place and hold finger on BMS reset
button for 10 or more seconds until LED #3 turns full on. The charge
program now automatically starts at STEP 3 or 4.
5
6
Lights when the battery connections are
5
6
24-7
24-7
for batteries with integrated battery management
24-7
24-7
4
4