STEP 8
State Of
Charge
2
TEST
STEP 9
OptiMATE
Bms
Bms
2
24-7
3
4
Maintain
12.8V
2 3 4
LFP / LiFePO
NOTES ON TEST RESULTS: The voltage of a cooled battery is directly proportional to its State Of Charge
percentage (SOC%). Immediately following charging a battery may briefly hold a higher voltage, as charging
Bms
Bms
raises the temperature of chemical elements within the battery. A battery recovered from a deep discharged
state may need longer to cool and voltage to settle and reflect its true state of charge (SOC%).
3
4
1. For any test result other than green #5, disconnect the battery from the electrical system it supports, and
reconnect the OptiMate Lithium. If a better test result is now obtained, this suggests that the power losses are
12.8V
partly due to an electrical problem in the electrical system and not in the battery itself.
12 3 4
NOTE: A sudden load being switched on while the charger is connected can cause the battery voltage to
LFP / LiFePO
reduce significantly and test result to worsen.
2. TEST LED #6 (red) flashing rapidly - Charging is suspended.
If it occured during -
a) a BMS reset: The battery has suffered damage (internal short circuit) or the connected circuitry is not allowing
the BMS pulse to be delivered to the battery.
b) STEP 3 SAVE mode: The charger has sensed that the battery is not accepting charge as expected. Try once
more and if the result repeats, do not charge again! A professional assessment is required.
c) STEP 8: STATE OF HEALTH TEST - the voltage reduced below 12.8V within the first 30 minutes, indicating
the battery cannot hold charge and may be damaged. A professional assessment is required.
More information on OptiMate TEST or MONITOR products can be found at www.optimate1.com.
MAINTAINING A LITHIUM BATTERY FOR EXTENDED PERIODS: A LiFePO
OptiMate Lithium for any extended period of time. The OptiMate Lithium maintenance program is fully
automatic, it continuously monitors the battery voltage and delivers current only if it sensed the battery has lost
charge (possibly through connected vehicle or other circuitry or self discharge). The OptiMate Lithium's
maintenance program guarantees the battery will remain at or close to full charge, but never overcharged.
ECO POWER SAVING MODE WHEN THE CHARGER IS CONNECTED TO AC SUPPLY:
The power converter switches to ECO mode when the charger is not connected to a battery resulting in a very
low power draw of less than 0.5W, equivalent to power consumption of 0.012 kWh per day. When a battery is
connected to the charger power consumption depends on the current demand of the battery and its connected
vehicle / electronic circuitry. After the battery has been charged and the charger is in long term maintenance
charge mode (to keep the battery at 100% charge) the total power consumption is estimated to be 0.024kWh or
less per day.
8
TEST after charge : Delivery of current to the battery is interrupted
LED #5 : GREEN
for 30 minutes** to allow the program to determine the battery's
ability to retain charge.
5
6
LED #5 (green) will remain on for batteries able to hold 90% or
higher state of charge (SOC%), otherwise the TEST result is adjusted
lower (LED #5 & 6, LED #6) in real time according to the measured
battery voltage. Consult the table on page 2 to match TEST LED
indication to an estimated state of charge percentage (SOC%).
Also read section "NOTES ON TEST RESULTS" below.
24-7
24-7
LED #5 / 6
5
The MAINTENANCE CHARGE CYCLE consists of 30 minute charge
6
periods followed by and alternating with a 30 minute 'rest' periods,
during which there is no charge current.
During the 30 minute charge cycles current is delivered only if the
battery has lost charge.
The BATTERY REFRESH CYCLE is performed if the charger detects the
battery has suddenly lost significant charge. The program reverts to
4
STEP 7 (LED #4) before returning to STEP 8 and STEP 9.
24-7
24-7
Read section MAINTAINING A LITHIUM BATTERY FOR EXTENDED
PERIODS.
4
** IF charging started in SAVE mode (LED #3) the voltage retention
test is extended to 12 hours to confirm battery health.
MAINTENANCE CHARGE: LED #5 / 6 steady on
according to final voltage measured at termination of STEP 8.
battery can be left connected to the
4