Pressure differences
The pressures of the cold and hot water connec-
tions must be balanced.
Adjustment
Correction is necessary if the temperature mea-
sured at the take off point differs from the tempe-
rature set on the scale. To adjust temperature pro-
ceed as follows: Turn the setting knob until water
at a temperature of 38° C comes out of the outlet.
Loosen screw of setting knob. Remove setting knob
and turn to the 38° C position. Attach setting knob
again and tighten its screw (please see page 10).
Temperature limitation
The temperature range is limited by the safe-
ty check to 38° C. If a higher temperature is
required, it is possible to override the 38° C check
by depressing the red safety button.
Safety Function
The desired maximum temperature for example
max. 42° C can be pre-set thanks to the safety
function (please see page 10).
Technical Data
Operating pressure:
Recommended operating pressure: 0,2 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Flow capacity at 0,3 MPa
Hand shower (1)
Body showers, 8 jets (2)
Hand shower + body showers (1+2) 22,3 l/min
Flow heater
Applicable for flow heaters at min. 24 kW and
0.15 MPa flow pressure before the Shower panel
and a minimum through flow of 7 l/minute. Only
one consumer possible, not two simultaneously.
6
English
Maintenance
There is no special maintenance for thermostats.
However, the non return valves (21) must be
checked regularly according to DIN EN 1717 in
accordance with national or regional regulations
(at least once a year). At this time, please also
check the filter situated on the MTC-ther-moelement
(16). After assembling the MTC-thermoelement
(16), it is necessary to check the water tempera-
ture at the take off point as described under the
expression „adjustment". Before the adjustment,
please check, if the warm water supply is activated
and the maximum temperature of the warm water
is available at the take off point.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Spare parts (see page 21)
1
2
3
4
5
6
7
8
max. 1 MPa
9
10
1,6 MPa
11
12
max. 80° C
13
65° C
14
15
16
17
16,8 l/min
18
18,0 l/min
19
20
21
22
upper cover
handshower
support, assy
hose
escutcheon
body shower
shut off unit with selector
holder for escutcheon
escutcheon
sleeve
adapter for handle
handle
handle for thermostat
adapter for handle
sleeve
thermostat cartridge
sealing set
mounting set
screw M5 x 20
noise reduction
non return valve
extension 25 mm
97324000
28518000
97117000
97325000
97326000
28406000
97327000
97328000
97329000
96446000
96451000
96421000
38391000
96435000
96439000
94282000
95037000
96179000
96525000
94073000
97350000
13595000

Publicidad

loading