Descargar Imprimir esta página

Klarstein KINGSVILLE 3.1 Manual De Instrucciones página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Gas requirements
Note: A gas pressure regulator approved according to EN 16129 and a gas hose
approved according to EN 16436-1 with a length of at least one metre must
be used for the device. If not included in the scope of delivery, these must be
purchased additionally.
Contact your local gas cylinder dealer for the exact use of your gas cylinders.
Never use a gas cylinder with a damaged tank, valve, base or ring.
A deformed or rusted gas cylinder can be dangerous and should therefore be
checked for functionality by your local gas cylinder dealer before use.
Never connect the appliance to a non-regulable gas source. Turn off the gas
when the appliance is not in use.
The appliance may only be operated with propane or butane gas or a gas
mixture of both types of gas. The gas bottle must not be dropped or handled
roughly. The gas bottle must be disconnected when the grill is not in use. After
disconnecting, put the cap back on the gas bottle.
Before connecting the gas bottle to the grill, make sure the gas valve is turned
off, there are no open flames near the appliance and the sealing ring is in
good condition. Then connect the pressure regulator to the gas bottle.
The connection hose must be replaced every two years.
Check the connection hose once a month and every time the gas cylinder is
changed. If the connection hose shows cracks or other signs of deterioration,
it must be replaced with a new one.
Make sure that the connection hose is not kinked or twisted and does not
come into contact with the surfaces of hot devices.
Before changing the gas bottle, make sure that the gas has been turned off
and that there are no naked flames or other heat sources near the appliance.
Make sure the gas cylinder is always in an upright position.
Only use the connections and accessories of the device for their intended
purposes.
Do not turn the gas bottle upside down to use the remaining gas.
Should local regulations require it, the flexible hose must be replaced.
EN
27

Publicidad

loading

Este manual también es adecuado para:

10045165