[001]-[005] Function Key Assignments
Function
Valid
Section
Button
Key
Range
[001]
1
00-68
[002]
2
00-68
[003]
3
00-68
[004]
4
00-68
[005]
5
00-68
Keypad Function Keys
Please see your system installation manual for more details on the function key options:
[00] - Null
[17] - Arm Interior
[02] - Instant Stay Arm
[21] - Command Output 1
[03] - Stay Arm
[22] - Command Output 2
[04] - Away Arm
[23] - Command Output 3
[05] - [*][9] No-Entry Arm
[24] - Command Output 4
[06] - Chime ON/OFF
[29] - Bypass Group Recall
[07] - System Test
[31] - Local PGM Activate
[09] - Night Arm
[32] - Bypass Mode
[12] - Global Stay Arm
[33] - Bypass Recall
[13] - Global Away Arm
[34] - User Programming
[14] - Global Disarming
[35] - User Functions
[16] - Quick Exit
[37] -Time and Date Program

Keypad Programming

Press [*][8][Installer Code]
[860] Keypad Slot Number
This is not for programming; the two-digit slot number is displayed for informational purposes only.
[861]-[876] Keypad Programming Sections
Sections [861]-[876] apply to keypad slot numbers 1-16 accordingly. After selecting the appropriate
keypad section number, the following programming options are available:
[000] Address of Partition
On selecting [000], a 2-digit entry is required to assign the keypad to a partition. Valid entries are 01-
08. The default is 01. NOTE:The HS2LCDWF keypad cannot be assigned as a global keypad.
[001]-[005] Function Key 1- 5 Assignment
[011] Keypad Input/Output Programming
Zone or PGM Number
000
|______|______|______|
[012] Local PGM Output Pulse Activation Time
|_____|_____| Minutes (00-99); |_____|_____| Seconds (00-99)
Default
Function
03
Stay Arm
|____|____|
04
Away Arm
|____|____|
06
Chime ON/OFF |____|____|
22
Comm Output 2 |____|____|
16
Quick Exit
|____|____|
[39] -Trouble Display
[40] - Alarm Memory
[61] - Partition Select 1
[62] - Partition Select 2
[63] - Partition Select 3
[64] - Partition Select 4
[65] - Partition Select 5
[66] - Partition Select 6
[67] - Partition Select 7
[68] - Partition Select 8
[021] First Keypad Options
Default
Opt.
ON
ON
|______|
1
Fire Key Enabled
ON
|______|
2
Medical Key Enabled
ON
|______|
3
Panic Key Enabled
Display Access Code When
ON
|______|
4
Programming
OFF
|______|
5
For Future Use
OFF
|______|
6
For Future Use
OFF
|______|
7
For Future Use
OFF
|______|
8
For Future Use
NOTE: For EN50131-1/EN50131-3 compliant systems, section [021]: options 1 and 2 shall be OFF.
[022] Second Keypad Options
Default
Opt.
ON
|______|
1
Local Clock Display ON
OFF
|______|
2
Local Clock Displays 24-hr Time Local Clock Displays AM/PM
ON
|______|
3
Auto Alarm Scroll ON
OFF
|______|
4
For Future Use
OFF
|______|
5
Power LED Enabled
ON
|______|
6
Power LED AC Present ON
ON
|______|
7
Alarms Displayed While Armed
OFF
|______|
8
Auto-Scroll Open Zones ON
[023] Third Keypad Options
Default
Opt
OFF
|______|
1 Armed LED On in Sleep Mode
ON
|______|
2 Keypad Status Shows Stay Arm Keypad Status Shows Stay/Away Arm
ON
|______|
4 Prox Tag Will Arm/Disarm
OFF
|______|
7 Temperature Display Enabled
Programming options indicated in GREY are required for systems compliant with EN50131-1 and
EN50131-3 standards. Section [023]: 1=OFF
[030] LCD Message
|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|
NOTE: Clock display (Section [022], Option 1) must be enabled.
[031] Downloaded LCD Message Duration
Default: 000 |______|______|______| (Valid entries are 000-255), 000=Unlimited Message Display.
This number represents the number of times the downloaded message must be cleared before it is per-
manently removed. Press any key to delete message.
[041] Indoor Temperature Zone Assignment
Default: 000 |______|______|______| (Valid entries are 000-128)
[042] Outdoor Temperature Zone Assignment
Default: 000 |______|______|______| (Valid entries are 000-128)
OFF
Fire Key Disabled
Medical Key Disabled
Panic Key Disabled
Display X's When Programming
Access Codes
For Future Use
For Future Use
For Future Use
For Future Use
ON
OFF
Local Clock Display OFF
Auto Alarm Scroll OFF
For Future Use
Power LED Disabled
Power LED AC Present OFF
Alarms Not Displayed While Armed
Auto-Scroll Open Zones OFF
ON
OFF
Armed LED Off in Sleep Mode
Prox Tag Does Not Arm/Disarm
Temperature Display Disabled