Mounting a guide rail with scale (Fig.
10. Loosely attach the eight carriage bolts (b) to the saw table (1)
and table width extender (6) on the side of the crank handle
(12) and the other operating elements with nuts (e). The bolt
heads must point outwards.
11. Thread both parts of the guide rail (7) onto the carriage bolts
on the saw table and table width extender. Assemble the two
parts of the guide rail.
12. Place the parallel guide (16) onto the guide rail (7) (Fig. 12).
Using the crank handle (12), crank the saw blade (4) out of
the saw table (1). Set it to position 0° on the scale (8) on the
front of the device.
Align the guide rail (7). Push the parallel guide (16) onto the
saw blade (4). Slide the guide rail (7) to the left or right until
the zero marking on the blue scale lines up with the sight
glass display (p) of the parallel guide (16).
If you have installed the parallel guide (16) and stop
rail (35), align based on the black scale.
13. Once the scale is aligned, tightly fasten the eight nuts of the
carriage bolts to fi x the guide rail in place.
Check the position of the riving knife before ini-
tial start-up. The riving knife is set to the lowest
position for transporting.
Mount/adjust the riving knife
14
16
(Fig.
-
)
Attention! Remove the mains plug! The setting
of the saw blade (4) must be checked whenever
a blade has been replaced.
1. Adjust the saw blade (4) to a max. cutting depth, move to the
0° position and lock in place.
2. Remove the saw blade guard (2) (not during initial assembly).
3. Remove the laser (28) by loosening the screws (z).
This step is omitted during initial assembly.
4. Loosen the two countersunk screws of the table insert (26)
and take out the table insert (5).
5. Loosen the mounting screw (27) using the enclosed open-end-
ed spanner (k), 8 across fl ats.
6. Slide the riving knife (3) all the way up. The distance between
the riveting knife and saw blade should be 3-5 mm.
7. Retighten the mounting screw (27).
8. Reattach the table insert (5).
9. Attach the laser (28) and the saw blade guard (2) if neces-
sary. See chapters "Attaching/removing the laser; inserting
the battery" and "Attaching/removing the saw blade guard".
When attaching the laser, also observe the chapter "Adjust-
ing the laser".
Attaching/removing the laser;
inserting the battery
17
18
(Fig.
+
)
Attaching the laser
1. As seen front the front, attach the laser (28) on the right on
the riveting knife (3) by fastening it with the screws (z). Ob-
serve the chapter "Adjusting the laser".
Removing the laser
2. Remove the laser (28) by loosening the screws (z).
Inserting the batteries
1. Move the On/Off switch of the laser (29) to the "0" position
(laser off).
10
13
-
)
2. Remove the battery compartment cover (31).
3. Insert the batteries supplied (type AAA), ensuring the correct
4. Insert the battery compartment cover (31).
Mounting / dismounting
the saw blade guard
1. Remove the screw with knurled nut and locknut (32) from the
2. Tighten the screw with knurled nut and locknut (32) as shown
3. Dismantling is carried out in reverse order. Caution! Before
Connect the suction device
1. Attach a suction hose to the suction adapter (17). If neces-
Replacing the Table Insert
1. If it is worn or damaged, the table insert (5) has to be re-
2. Remove the 2 countersunk screws (26).
3. Slightly raise the table insert (5) at the back and slide backwards
4. The new table insert is mounted in reverse order.
Attaching/changing the saw blade
1. Attention! Remove the mains plug and wear pro-
2. Remove the saw blade guard (
3. Remove the laser (
4. Remove the table insert (
5. Loosen the clamping screw (
6. Place the Allen key (h) (HX 6) on the bolt and use the ring
7. Attention! Turn the bolt in the direction of rotation of the
8. Remove the outer fl ange and take the old saw blade off the
18
polarity (see Fig.
).
Notes concerning the batteries:
If you are not going to use the laser for a prolonged period,
remove the batteries from the battery compartment. Otherwise,
the leaking of battery fl uid might damage the device.
Do not place the batteries on radiators or expose them for a
prolonged period to strong sunlight; temperatures above 45°
could damage the device.
19
(Fig.
)
saw blade guard (2). Place the saw blade guard (2) onto the
riving knife (3) from above.
and tighten the two nuts one after another. The saw blade
guard must be able to move freely.
you start sawing, the saw blade guard (2) has to be lowered
onto the item being sawn.
20
(Fig.
)
sary, secure the suction hose with a hose clamp to prevent it
from slipping off the suction adapter (17).
A household vacuum cleaner is not suitable as a suc-
tion device. Use a multi-purpose vacuum cleaner or a
swarf extraction machine.
14
(Fig.
)
placed, as otherwise there is an increased risk of injury.
in the direction of the arrow. Take out the table insert (5). The left-
hand side of the central part of the table insert (5) may require
slight adjustment to release the nose of the table insert (5).
21
(Fig.
)
tective gloves.
– 28), by loosening the screws (z).
17
14
Insert")
by turning the handwheel (
len key (h) and ring spanner (k) more easily.
spanner (k) (AF 22) to stop the motor schaft from turning.
saw blade. Remove the loosened screw.
inner fl ange by pulling downwards and diagonally.