Fault Correction - Franke AQRE130 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

19. Fault Correction

Fault
Water does not flow
Water flows
continuously
Water flow too weak
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
10
Cause
– Battery dead (red LED lights up)
– Water flow regulator closed
– Grit filters are clogged with dirt
– Cleaning clip in front of the fitting
– Electronic system in sleep mode
– Solenoid valve faulty
– Solenoid valve faulty
– Corner valves not fully opened
– Grit filters are clogged with dirt
– Aerator calcified
– Supply pressure too low
– Cold water is turned off
– Filter in cold-water part is dirty
– Non-return valve faulty
– Hot water is turned off
– Filter in hot-water part is dirty
– Non-return valve faulty
Remedy
➯ Replace it
➯ Open it
➯ Clean them
➯ Remove it
➯ Shine bright light
in front of the
sensor
➯ Replace it
➯ Replace it
➯ Open them
➯ Clean them
➯ Clean it
➯ Check it
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Replace it
➯ Replace it

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aqre131Aqre13276 12982 08547576 12982 08548276 12982 085499

Tabla de contenido