Maintenance
4.2.1
Cleaning and disinfecting procedure
1. Remove the respiratory filter.
2. Prepare a cleaning solution of water and detergent.
3. Clean all parts with a soft cloth and a cleaning solution.
4. Rinse all parts thoroughly under running water.
5. Prepare a disinfection bath made from water and a disinfectant.
6. Place any parts that need to be disinfected in the disinfection bath.
7. Rinse all parts thoroughly under running water.
8. Allow all parts to air-dry or be dried in the drying cabinet
(temperature: max. 60 °C (140 °F)). Do not expose to direct
sunlight.
4.3

Maintenance work

4.3.1
Examining the half mask
Examine all parts for cracks, brittleness or deformation.
4.3.2
Examining the exhalation valve disc
1. Press the valve seat into the inner mask body and remove it from
the mask.
2. Grasp the exhalation valve disk at the edge and remove it from the
valve seat.
3. Examine the valve seat for dirt and damage, and wipe it clean with
a disposable tissue if necessary.
4. Press the exhalation valve disc into the valve seat until it engages.
The disc should rest evenly on the valve seat. If necessary replace
the valve disc.
5. Insert the valve seat into the mask body so that the valve disk
points to the outside.
6. Press the valve seat into the groove of the mask body.
24