Receiver Back Panel
① AC Power Input
IEC locking connector, 100 - 240 V AC.
② AC Power Protection Fuse
Protects the AC power cascade from overloads.
③ AC Power Cascade (locking)
Use IEC extension cables to loop power through multiple devices.
④ Ethernet Ports
Four Ethernet ports carry the following signals:
◦
ctrl 1: Network control
◦
ctrl 2: Network control
◦
Dante Primary: Dante digital audio
◦
Dante Secondary: Dante digital audio
Network Status (green) LEDs:
◦
Off: no network link
◦
On: network link active
◦
Flashing: network link active, rate corresponds to traffic volume
Network Speed (amber) LEDs:
◦
Off = 10/100 Mbps
◦
On = 1 Gbps
⑤ Word Clock Input and Thru Ports
◦
Input: Connect to an external word clock to resolve the AES3 digital output
◦
Thru: Passes word clock signal to additional components
⑥ AES3 Switch
Enables AES3 output on Output 3 and Output 4. This disables analog output on XLR Output 1 and XLR Output 2.
⑦ Word Clock Termination Switch
◦
Set to Thru when passing signal to additional components
◦
Set to Term 75Ω when Thru connection is not used